Description
This product can measure the particle beam current below the milliampere level. Monitor thousands of amperes of pulse current due to power supply failure. It can be used to monitor the transient current pulse with short picosecond rising edge; the large aperture test probe makes it possible for you to test the high-voltage pulse current without breaking down your current probe. The product is sealed and can be used in high voltage insulating oil or vacuum. The output signal can be connected to oscilloscope, spectrum analyzer, power analyzer, digital voltmeter, analog-to-digital converter, and other kinds of measuring instruments.
Model | Frequency Range (Usable) | Zt ohms | Maximum Output Voltage Vom | Saturation Current A | Average Current MAX (CW) A | Peak Current A | Pulse Width MAX usec | Rep Rate KHz |
IP-2-1 | 100 KHz-1.3 GHz | 1.00 | 400 | 2.94 | 2.87 | 284 | 0.20 | 6.36 |
IP-2-5 | 125 KHz-800 MHz | 5.00 | 1000 | 1.68 | 13.23 | 180 | 0.02 | 56963 |
IP-2-10 | 500 KHz-1 GHz | 10.00 | 1000 | 2.07 | 7.35 | 100 | 0.01 | 56963 |
I-075-1B | 40 KHz-150 MHz | 5.00 | 2000 | 27.74 | 35.15 | 360 | 0.22 | 3995 |
I-075-1C | 120 KHz-420 MHz | 5.00 | 400 | 27.51 | 1.24 | 64 | 0.31 | 1.21 |
I-125-1A | 10 KHz-100 MHz | 5.00 | 2000 | 1259 | 39.40 | 320 | 2.06 | 478 |
I-125-1B | 50 KHz-130 MHz | 5.00 | 2000 | 39.45 | 35.15 | 360 | 0.37 | 2389 |
I-125-1HF | 50 KHz->1 GHz | 5.00 | 400 | 29.93 | 1.29 | 76 | 0.50 | 0.58 |
I-125-1D | 1 KHz-110 MHz | 5.00 | 2000 | 57.33 | 27.87 | 360 | 1.00 | 697 |
I-125-1E | 850 Hz-120 MHz | 5.00 | 2000 | 9.82 | 44.10 | 360 | 0.52 | 2103 |
I-125-2A | 10 KHz- 150 MHz | 1.00 | 400 | 1125 | 4.27 | 456 | 9.01 | .01 |
I-125-2C | 300 Hz-25 MHz | 1.00 | 2000 | 50.03 | 146 | 1880 | 5.22 | 697 |
I-125-2HF | 50 KHz->1 GHz | 1.00 | 400 | 42.66 | 4.43 | 400 | 1.66 | .15 |
I-125-3A | 1 KHz-250 MHz | 0.03 | 400 | 878.84 | 23.20 | 13397 | 10.30 | .01 |
I-125-4A | 1 KHz-150 MHz | 0.10 | 400 | 879.75 | 12.85 | 4064 | 10.30 | .01 |
I-125-6A | 20 Hz-30 MHz | .50 | 2000 | 9.82 | 258 | 4200 | 6.12 | 1055 |
I-125-7 | 400 Hz-100 MHz | 1.00 | 400 | 20.80 | 11.33 | 389 | 15.55 | .06 |
I-125-9 | 1 KHz-270 MHz | .005 | 400 | 25502 | 60.05 | 80072 | 5.00 | .01 |
I-262-2A | 10 KHz-50 MHz | 5.00 | 2000 | 1865 | 99.61 | 320 | 4.60 | 542 |
I-262-3A | 10 KHz-140 MHz | 2.00 | 400 | 1690 | 2.32 | 232 | 11.50 | .01 |
I-262-4A | 10 KHz-100 MHz | .06 | 400 | 1832 | 12.99 | 6707 | 14.36 | .01 |
I-262-5A | 10 KHz-200 MHz | 1.00 | 400 | 1158 | 2.60 | 424 | 8.61 | .01 |
I-262-6B | 10 KHz-150 MHz | .10 | 400 | 1468 | 9.02 | 4032 | 11.50 | .01 |
I-300B | 180 KHz-300 MHz | 5.00 | 2000 | 3.86 | 30.97 | 400 | 0.02 | 35556 |
I-310B | 50 KHz-200 MHz | 1.00 | 400 | 2.64 | 4.98 | 395 | 0.16 | 0.97 |
I-320B | 200 KHz-500 KHz | 1.00 | 400 | 0.94 | 2.78 | 352 | 0.05 | 1.35 |
I-400A | 50 KHz->450 MHz | 5.00 | 2000 | 13.19 | 30.97 | 400 | 0.15 | 5338 |
I-410A | 15 KHz-.450 MHz | 1.00 | 400 | 22.33 | 4.98 | 395 | 0.73 | .22 |
I-2400-12 | 5 Hz-2 MHz | .001 | 3000 | 17002 | 8820 | 3000000 | 508.06 | .01 |
CURRENT INJECTORS: | ||||||||
IT-050-1 | 100 KHz-100 MHz | 500.00 | 2000 | 38.70 | 30.97 | 4 | 0.79 | 975 |
IT-075-1 | 100 KHz-100 MHz | 500.00 | 2000 | 44.65 | 30.97 | 4 | 0.79 | 975 |
IT-125-1 | 100 KHz-100 MHz | 500.00 | 2000 | 53.58 | 30.97 | 4 | 0.64 | 1219 |
IT-125-2 | 50 KHz-700 MHz | 50.00 | 2000 | 53.58 | 3.10 | 40 | 0.06 | 1219 |