Hotline
010-8840 8841

Current Probe

Products > Test Accessories > Current Probe

Current Probe

This product can measure the particle beam current below the milliampere level. Monitor thousands of amperes of pulse current due to power supply failure. It can be used to monitor the transient current pulse with short picosecond rising edge; the large aperture test probe makes it possible for you to test the high-voltage pulse current without breaking down your current probe.

Description

This product can measure the particle beam current below the milliampere level. Monitor thousands of amperes of pulse current due to power supply failure. It can be used to monitor the transient current pulse with short picosecond rising edge; the large aperture test probe makes it possible for you to test the high-voltage pulse current without breaking down your current probe. The product is sealed and can be used in high voltage insulating oil or vacuum. The output signal can be connected to oscilloscope, spectrum analyzer, power analyzer, digital voltmeter, analog-to-digital converter, and other kinds of measuring instruments.


Specification
ModelFrequency Range
   
(Usable)
Zt
   ohms
Maximum Output
   Voltage
   
Vom
Saturation
   Current

   A
Average Current
   MAX (CW)

   A
Peak
   Current

   A
Pulse Width
   MAX
   
usec
Rep Rate       
   
KHz
       IP-2-1       100    KHz-1.3 GHz       1.00       400       2.94       2.87       284       0.20       6.36
IP-2-5125    KHz-800 MHz5.0010001.6813.231800.0256963
IP-2-10500    KHz-1 GHz10.0010002.077.351000.0156963
I-075-1B40    KHz-150 MHz5.00200027.7435.153600.223995
I-075-1C120    KHz-420 MHz5.0040027.511.24640.311.21
I-125-1A10    KHz-100 MHz5.002000125939.403202.06478
I-125-1B50    KHz-130 MHz5.00200039.4535.153600.372389
I-125-1HF50    KHz->1 GHz5.0040029.931.29760.500.58
I-125-1D1    KHz-110 MHz5.00200057.3327.873601.00697
I-125-1E850    Hz-120 MHz5.0020009.8244.103600.522103
I-125-2A10    KHz- 150 MHz1.0040011254.274569.01.01
I-125-2C300    Hz-25 MHz1.00200050.0314618805.22697
I-125-2HF50    KHz->1 GHz1.0040042.664.434001.66.15
I-125-3A1    KHz-250 MHz0.03400878.8423.201339710.30.01
I-125-4A1    KHz-150 MHz0.10400879.7512.85406410.30.01
I-125-6A20    Hz-30 MHz.5020009.8225842006.121055
I-125-7400    Hz-100 MHz1.0040020.8011.3338915.55.06
I-125-91    KHz-270 MHz.0054002550260.05800725.00.01
I-262-2A10    KHz-50 MHz5.002000186599.613204.60542
I-262-3A10    KHz-140 MHz2.0040016902.3223211.50.01
I-262-4A10    KHz-100 MHz.06400183212.99670714.36.01
I-262-5A10    KHz-200 MHz1.0040011582.604248.61.01
I-262-6B10    KHz-150 MHz.1040014689.02403211.50.01
I-300B180    KHz-300 MHz5.0020003.8630.974000.0235556
I-310B50    KHz-200 MHz1.004002.644.983950.160.97
I-320B200    KHz-500 KHz1.004000.942.783520.051.35
I-400A50    KHz->450 MHz5.00200013.1930.974000.155338
I-410A15    KHz-.450 MHz1.0040022.334.983950.73.22
I-2400-125    Hz-2 MHz.00130001700288203000000508.06.01
CURRENT    INJECTORS:                             
IT-050-1100    KHz-100 MHz500.00200038.7030.9740.79975
IT-075-1100    KHz-100 MHz500.00200044.6530.9740.79975
IT-125-1100    KHz-100 MHz500.00200053.5830.9740.641219
IT-125-250    KHz-700 MHz50.00200053.583.10400.061219