Description
This test set-up can be used for the susceptibility testing of small pieces of equipment such as printed boards, small subsystems, etc., according to MIL-STD-461 / RS105 (NEMP: nuclear electromagnetic pulse). The system consists of a control unit and a line assembly including the high voltage unit directly connected to the radiating line. The high voltage unit and the antenna are fixed on a stable and solid frame which can be easily moved and placed on a table. The control unit is connected to the line structure through a high voltage cable and a control cable. The test system can be controlled by a computer through RS232 and USB interface. The minimum field under the line is 50 kV/m at full charging voltage. Even higher fields can be achieved for smaller objects placed close to the beginning of the line.
Applications
The radiation line shall be connected to the high voltage pulse generator forMIL-STD-461 RS105test.
Specification
REFERENCE | LINEHEIGHT | LINELENGTH | EUTMAXHEIGHT | REMARKS |
RL50-50 | 0.5 m | 2.0 m | 0.17 m | MIL-STD-461 E/F/G RS105 AECTP 500 NRS03 IEC 61000-4-25 |
RL140-50 | 1.4 m | 6.0 m | 0.45 m | |
RL360-50 | 3.6 m | 16.4 m | 1.1 m | |
RL500-50 | 5.0 m | 18.4 m | 1.7 m | |
RL730-50 | 7.3 m | 25.6 m | 2.4 m | |
RL1080-50 | 10.8 m | 62 m | 3.2 m | |
RL1290-50 | 12.9 m | 74 m | 3.7 m | |
RL1800-50 | 18.0 m | 103 m | 5.0 m | |
RL2500-50 | 25.0 m | 143 m | 8.3 m |